Journal of the Korean Orthopaedic Association
2006 Volume.41 No. 4 p.687 ~ p.694
The Harris-Galante-II Acetabular Componentin Cementless Total Hip Arthroplasty- Average Ten-year Follow-up Results -
Chang Jun-Dong

Yoo Je-Hyun
Lee Sang-Soo
Kwon Soon-Eok
Abstract
Purpose: To evaluate the average ten-year follow-up results of 98 total hip arthroplasties using Harris-Galante-II porous-coated acetabular components.

Materials and Methods: Ninety-eight hips were evaluated. The mean age of the patients was 45 years, and the mean follow-up was 121 months. The clinical and radiographic findings including the wear of the polyethylene liner were evaluated. The endurance of the acetabular component was analyzed using the Kaplan-Meier method.

Results: Retroacetabular osteolysis, dissociation of the PE liner and aseptic loosening of the acetabular component was observed in 25 hips (25.5%), 9 hips (9.2%), and 1 hip (1.0%), respectively. The average rate of liner wear was 0.16 mm/year. Twenty acetabular components (20.4%) were revised, and the survival probability of the acetabular components at 10 years was 87% (95% confidence limits, 83-90%).

Conclusion: In this long-term follow-up study, the revision rate of Harris-Galante-II acetabular component was relatively high, and was associated with locking mechanism failure and retroacetabular osteolysis. However, the rarity of aseptic loosening suggests that excellent long-term fixation could be achieved with the surface treatment of a fiber-metal porous coating.
KEYWORD
Total hip arthroplasty, Harris-Galante-II acetabular component