Esophageal Fistula Formation by Metal Loosening following Anterior Cervical Arthrodesis - A Case Report -
Song Kyung-Jin

Kim Gyu-Hyung
Park Jong-Hyuk
Lee Jun-Mo
Abstract
An esophageal injury after an anterior cervical discectomy and fusion with plating is a well known but a fatal complication. If the diagnosis is delayed, inflammation can spread out into the neighboring main organs resulting in a very poor prognosis despite vigorous treatment. W e report a case of esophageal fistula formation as a result of infected metal loosening after an anterior cervical discectomy and fusion with plating, which was treated successfully with a satisfactory clinical outcome.
KEYWORD
Esophageal fistula, Anterior cervical fusion, Metal loosening