Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0361620110460060457
Journal of the Korean Orthopaedic Association
2011 Volume.46 No. 6 p.457 ~ p.463
Long-Term Changes of the Clinical and Nerve Electrophysiological Findings after Endoscopic Carpal Tunnel Release
Cheon Sang-Jin

Moon Kyu-Pill
Lim Jong-Min
Abstract
Purpose: The aim of this study was to analyze the clinical symptoms and function and the nerve electrophysiological changes between the pre-operative and long-term post-operative states of patients who underwent surgical treatment with endoscopic release of the carpal tunnel for idiopathic carpal tunnel syndrome.

Materials and Methods: This study was performed in 48 patients and 88 wrists with idiopathic carpal tunnel syndrome. All patients were treated with endoscopic carpal tunnel release using a single portal. The preoperative and the 3 years 5 months long-term postoperative clinical symptoms and function were evaluated using the Boston carpal tunnel questionnaire. The nerve electrophysiological status was evaluated using the Bland grade system.

Results: When the preoperative Bland grade was 2, 3, 4, 5, and 6, the range of the change of the symptom severity score was 1.38, 1.68, 2.40, 1.61 and 1.28, respectively, and the range of the change of the functional status score was 0.60, 1.34, 1.58, 0.93 and 0.88, respectively, at the long-term follow-up. The clinical symptoms were signifi cantly improved at the fi nal follow-up when the preoperative Bland grade was 2, 3, 4 and 5. The function was signifi cantly improved for all the preoperative Bland grades. On the nerve electrophysiological study, there was statistical improvement of the distal motor latency of the motor nerve and the nerve conduction velocity and amplitude of the sensory nerve. When the preoperative Bland grade was 2, 3, 4, 5 and 6, the extent of improved grade was 0.60, 0.75, 2.17, 2.87 and 4.25, respectively, at the long-term follow-up, and the Bland grade was signifi cantly improved when the preoperative Bland grade was 3, 4, 5 and 6. However, there was no statistical signifi cance between the Bland grade and the clinical state at the long-term follow-up.

Conclusion: The clinical and nerve electrophysiological states were significantly improved at the long-term follow-up after endoscopic carpal tunnel release. When the preoperative Bland grade was 3, 4 and 5, the clinical symptoms, function and the nerve electrophysiological states were signifi cantly improved at the long-term follow-up.
KEYWORD
idiopathic carpal tunnel syndrome, endoscopic carpal tunnel release, long-term follow-up outcomes, Boston carpal tunnel questionnaire, Bland grade
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø