KMID : 0361620170520040364
|
|
Journal of the Korean Orthopaedic Association 2017 Volume.52 No. 4 p.364 ~ p.369
|
|
Delayed Rupture of the Extensor Pollicis Longus Tendon Following Intramedullary Nailing of Radial Shaft Fracture
|
|
Park Jin-Yeong
Huh Soon-Ho Jung Bo-Hyun
|
|
Abstract
|
|
|
Delayed rupture of the extensor pollicis longus tendon mostly occur after plate fixation of distal radius fracture. However, delayed rupture of the extensor pollcis longus tendon following intramedullary nailing of radial shaft fracture is very rare. We report one case of delayed rupture of the extensor pollicis longus tendon following intramedullary nailing, presenting abnormal signs from adhesion of the extensor pollicis longus with extensor indicis at the nail insertion site.
|
|
KEYWORD
|
|
tendon injuries, tendon transfer, radius fractures
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|