Tensile Bond Strength of Glass Ionomer Cements


Abstract
This study was conducted to evaluate the tensile bond strength of three commercially available glass ionomer cements as orthodontic bracket adhesives.
120 premolars extracted for orthodontic treatment were prepared for bonding and standard edgewise brackets were bonded with Shofu GlasIonomer Cement (Shofu Co., U.S.A.), GC Fuji I(GC Co., Japan), KETAC-CEM(ESPE Co., West Germany) with different
P/L
ratio. The tensile bond strength was tested by Instron testing device after 24hours and 3months from bonding. After debracketing, bracket bases were examined to determine the failure sites.
@ES The results of this study were as follows:
@EN 1. KETAC-CEM showed the highest bond strength other than measurement after 24 hours and at its original P/L ratio, and seemed to have clinically a proper bond strength. It seemed, however, that both Shofu GlasIonomer Cement and GC Fuji I had
an
inappropriate bond strength.
2. The incorporation of additional powder into the mixture improved the tensile bond strength.
3. Prolonged storage time improved the tensile bond strength.
4. Of the failure, failure occured at the tooth-adhesive interface(54.2%) was the most common type. The second type of failure(36.7%) was combination type, where part of the adhesive remained on the tooth and part on the bracket. And the last
type
of
failure(9.1%) occured at the adhesive-bracket interface.