A study on the release of nickel and chromium from simulated orthodontic appliances



Abstract
Nickel and chromium are two major metals used in the alloys of most orthodontic appliances. But these metals. are known to cause hypersensitivity, dermatitis, and asthma. In addition, a significant carcinogenic and mutagenic potential has been demonstrated for compounds containing these metals. The purpose of this study was to find out how much nickel and chromium was released from orthodontic appliances, and which factors would influence the release. The simulated orthodontic appliances were constructed for a half of a mandibular arch and incubated in 0.059¢¥o NaCl solution at 37t. Nickel and chromium release was quantified with an Inductively Coupled Plasma (ICP) spectroanalyzer.

The results were as follows

1. From simulated orthodontic appliances, nickel was released 9.83-70.0g/Jay but the release of chromium was not detectable in limit of 10ppb. `
2. The amount of nickel release was significantly different between the types of appliances.
3. The galvanic condition increased the amount of nickel release, which was not statistically significant. 4. The. sand blasting increased the amount of nickel release, which was also riot statistically significant.
KEYWORD
FullTexts / Linksout information
  
Listed journal information
SCI(E) ÇмúÁøÈïÀç´Ü(KCI) KoreaMed