Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0361920070370030182
Korean Journal of Orthodontics
2007 Volume.37 No. 3 p.182 ~ p.191
Validity of midsagittal reference planes constructed in 3D CT images
Jeon Ye-Na

Lee Ki-Heon
Hwang Hye-Nam
Abstract
Objective: The purpose of this study was to evaluate the validity of midsagittal reference (MSR) planes constructed in maxillofacial 3D images.

Methods: Maxillofacial computed tomography (CT) images were obtained in 36 normal occlusion individuals who did not have apparent facial asymmetry, and 3D images were reconstructed using a computer software. Six MSR planes (Cg-ANS-Ba, Cg-ANS-Op, Cg-PNS-Ba, Cg-PNS-OP, FH{perp}(Cg, Ba), FH{perp}(Cg, Op)) were constructed using the landmarks located in the midsagittal area of the maxillofacial structure, such as Cg, ANS, PNS, Ba and Op, and FH plane constructed with Po and Or. The six pairs of landmarks (Z, Fr, Fs, Zy, Mx, Ms), which represent right and left symmetry in the maxillofacial structure, were selected. Statistically significant differences of the right and the left measurements were examined through t-test, and the difference of the right and the left measurement was compared among the six MSR planes.

Results: The distances from the right and the left landmarks in each pair to each MSR plane did not show a statistically significant difference. The reproducibility of the landmark identification was excellent.

Conclusion: All the six planes constructed in this study can be used as a MSR plane in maxillofacial 3D analysis, particularly, the planes including Cg and ANS.
KEYWORD
Maxillofacial computerized tomography, 3D images, Midsagittal reference plane
FullTexts / Linksout information
  
Listed journal information
SCI(E) ÇмúÁøÈïÀç´Ü(KCI) KoreaMed