KMID : 0361920070370060400
|
|
Korean Journal of Orthodontics 2007 Volume.37 No. 6 p.400 ~ p.406
|
|
Influence of immediate loading on the removal torque value of mini-screws
|
|
Sun Seung-Bum
Kang Yoon-Goo Kim Seung-Hun Mo Sung-Seo Kook Yoon-Ah
|
|
Abstract
|
|
|
The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model.
Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed.
Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups.
Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.
|
|
KEYWORD
|
|
Immediate orthodontic loading, Orthodontic miniscrews, Removal torque
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|