Korean Journal of Orthodontics
2011 Volume.41 No. 1 p.6 ~ p.15
Finite element analysis of peri-implant bone stresses induced by root contact of orthodontic microimplant
Yu Won-Jae

Kim Mi-Ryoung
Park Hyo-Sang
Kyung Hee-Moon
Kwon Oh-Won
Abstract
Objective : The aim of this study was to evaluate the biomechanical aspects of peri-implant bone upon root contact of orthodontic microimplant.

Methods: Axisymmetric finite element modeling scheme was used to analyze the compressive strength of the orthodontic microimplant (Absoanchor SH1312-7, Dentos Inc., Daegu, Korea) placed into inter-radicular bone covered by 1 mm thick cortical bone, with its apical tip contacting adjacent root surface. A stepwise analysis technique was adopted to simulate the response of peri-implant bone. Areas of the bone that were subject to higher stresses than the maximum compressive strength (in case of cancellous bone) or threshold stress of 54.8MPa, which was assumed to impair the physiological remodeling of cortical bone, were removed from the FE mesh in a stepwise manner. For comparison, a control model was analyzed which simulated normal orthodontic force of 5 N at the head of the microimplant.

Results: Stresses in cancellous bone were high enough to cause mechanical failure across its entire thickness. Stresses in cortical bone were more likely to cause resorptive bone remodeling than mechanical failure. The overloaded zone, initially located at the lower part of cortical plate, proliferated upward in a positive feedback mode, unaffected by stress redistribution, until the whole thickness was engaged.

Conclusions : Stresses induced around a microimplant by root contact may lead to a irreversible loss of microimplant stability.
KEYWORD
Microimplant, Root contact, Peri-implant bone stress, Finite element analysis