KMID : 0361920140440010044
Korean Journal of Orthodontics
2014 Volume.44 No. 1 p.44 ~ p.49
Effects of ultrasonic instrumentation with different scaler-tip angulations on the shear bond strength and bond failure mode of metallic orthodontic brackets
Bonetti Giulio Alessandri

Parenti Serena Incerti
Ippolito Daniela Rita
Gatto Maria Rosaria
Checchi Luigi
Abstract
Objective: To evaluate the effects of ultrasonic instrumentation with different scaler-tip angulations on the shear bond strength (SBS) and bond failure mode of metallic orthodontic brackets.

Methods: Adhesive pre-coated metallic brackets were bonded to 72 extracted human premolars embedded in autopolymerizing acrylic resin. The teeth were randomly divided into 3 groups (n = 24 each) to undergo no treatment (control group) or ultrasonic instrumentation with a scaler-tip angulation of 45o (45o-angulation group) or 0o (0o-angulation group). SBS was tested in a universal testing machine,and adhesive remnant index (ARI) scores were recorded. The Kruskal-Wallis test and Mann-Whitney U-test were used for statistical analysis.

Results: The control group had a significantly higher mean SBS value than the treated groups, which showed no significant differences in their mean SBS values. The ARI scores were not significantly different among the groups.
Conclusions: Ultrasonic instrumentation around the bracket base reduces the SBS of metallic orthodontic brackets, emphasizing the need for caution during professional oral hygiene procedures in orthodontic patients. The scaler-tip angulation does not influence the SBS reduction and bond failure mode of such brackets.
KEYWORD
Bracket, Bonding, Oral hygiene, Ultrasonics