KMID : 0362120040260010209
Journal of Technologic Dentistry
2004 Volume.26 No. 1 p.209 ~ p.216
Implant supported over denture with O-ring abutment
Lee Sung-Uck

Lee Jung-Hwan
Abstract
The purpose of this study is to introduce how to make implant supported over denture with O-ring.Many kinds of attachments have used to dental restorations. The application of attachment haswidely increased implant fixed prosthesis and implant supported over denture.In order that implant supported over denture have properly retention, generally used O-ring,magnetic, bar attachment. O-ring give us an advantage that is required more minimum verticaldimension than bar-type and easily replace with new part.When we make these prosthesis using O-ring, Bar, Ball attachment, we should followingprocedures. Strong occlusion force leads to fracture of over denture because part of functionalmechanism as implant abutment or attachment is spaced.Clips are regularly activated. O-ring and springs are changed every year. The pattern ofresorption should be carefully monitored and compensated for by relining procedures.If the over denture appears to rest on the bar or the ball attachments, relining should beperformed and clips/caps should be changed.