Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0362120090310030021
Journal of Technologic Dentistry
2009 Volume.31 No. 3 p.21 ~ p.26
A Study on the Viability of Human Dermal Fibroblast Cell by Media for Ni-Cr alloy elution
Kim Kap-Jin

Kim Chi-Young
Choi Sung-Min
Abstract
Purpose: Standards of alloy for porcelain fused to metal crown be classified by metallic factor and biological factor. Metallic factors consist of stability of alloy composition and mechanical strength and surface characteristics for chemical bond. Biological factors be considered properties of metallic elements and problems originated by toxicity and hypersensitive reaction. Alloys considered such controversial points are the most suitable alloy for dental instrument.

Method: Alloys added Be and Nb using Ni-Cr alloy which has been widely used for dental instrument be selected and classified experimental group. Non-addition Be and Nb to Ni-Cr alloy classify control group and addition Be alloy is Be-experimental group, addition Nb alloy is Nb-experimental group. Specimens for cytotoxicity analysis gave effect to washing and sterilization. and then made an experiment on elution with cell medium after disinfection. It conducted specimens within cell medium with 24hours, 48hours, 72hours, respectively. It cultured human dermal fibroblast(HDF) using cell medium for cytotoxicity test and then investigated elution rate through spectroscopic analysis by MTT-assay.

Result: As results of cytotoxicity test by MTT-assay, cultured cell rate of VII measured more low numerical value within elution medium for 24hours focused on control group. Also, cultured cell rate of K3 alloys observed low value for 48hours, 72hours than value of control group.

Conclusion: According to final result that synthesize above results, Ni-Cr alloy added Be and Ni has little difference in Cytotoxicity by MTT-assay.
KEYWORD
Ni-Cr alloy, cytotoxixity, MTT assay, Human detmal fibroblast, HDF
FullTexts / Linksout information
Listed journal information