Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0362120110330010047
Journal of Technologic Dentistry
2011 Volume.33 No. 1 p.47 ~ p.54
Effect of Surface Condition on the Bonding Characteristics of 3Y--Metal Bracket System
O Seon-Mi

Kim Jin-seong
Lee Chae-Hyun
Abstract
Purpose: To investigate shear bonding strength between dental zirconia ceramics with different surface treatment and metal bracket.

Methods: Zirconia ceramics(LAVA, 3M ESPE, USA) were divided to 4 groups according to their surface treatment; no surface treatment(G1), sand blasting(G2), silane coating(G3), and sand blasting+silane coating(G4). Specimens were bonded to metal bracket using resin bond(, 3M Unitek, USA). Shear bond strength was measured using universal test machine(3366 INSTRON. U.S.A) with cross head speed of 1 mm/min. Microstructural investigation for fracture surface was performed after shear test.

Results: Shear bonding strengths of single surface treatment groups (G2 and G3) were higher than no treatment group(G1). Combined Treatment Group (G4) showed the highest shear bond strength of 9.15MPa. Microstructural observation shows that higher shear bonding strength was obtained when debonding was occurred at metal bracket/resin interface rather than zirconia ceramic/resin interface.

Conclusion: Surface treatment of zirconia is necessary to obtain higher bonding strength. Combined treatment can be more effective when surface the surfaces are kept clean and homogeneous.
KEYWORD
3Y-, bracket, bonding characteristics, surface condition
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)