Purpose: The aim of study was to compare the dimensional stability of digitized dental stone replica using different color of gypsum materials using a white light scanner with three- dimensional software.
Methods: A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Several type stones(white, yellow, green) were used for 30 stone casts(10 casts each) duplicated a master model of mandible. The master model and the replicas were digitized with the non -contacting white light scanner to create 3-dimensional digital models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad (Delcam plc, UK) 3D graphic software. One-way analysis of variance(ANOVA) combined with a Tukey multiple-range test were used to analysis the data( =0.05).
Results: There were considerable differences in mean values between gypsum materials within each color(white, yellow, green), and this difference was statistically significant, p=0.001.
Conclusion: Digitization of dental materials on optical scanner was affected by color. Three different color of gypsum materials showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.
|
|