Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0362120150370040213
Journal of Technologic Dentistry
2015 Volume.37 No. 4 p.213 ~ p.218
Comparison of reproducibility of prepared tooth impression scanning utilized with white and blue light scanners
ÀüÁøÈÆ:Jeong Jin-Hun
¼ºÈ¯°æ:Sung Hwan-Kyung/¹Îº´±¹:Min Byung-Kuk/ȲÀç¼±:Hwang Jae-Sun/±èÁöȯ:Kim Ji-Hwan/±è¿õö:Kim Woong-Chul
Abstract
Purpose: The purpose of this study compared of reproducibility of prepared tooth impression scanning utilized with white and blue light scanners.

Methods: To evaluate reproducibility with white and blue light scanners, the impression of premolar were rotated by 10¡Æ~20¡Æ and scanned. These data were compared with the first 3-D data (STL file), and the error sizes were measured (n=5). Independent t test was used to evaluation the reproducibility of impression of premolar with white versus blue light scanners through discrepancies of mean, RMS (¥á=0.05).

Results: Discrepancies of mean with regard to reproducibility were 11.2§­, 5.8§­, respectively, with white and blue light scanners (p<0.047). And discrepancies of RMS with regard to reproducibility were 33.4§­, 18.8§­, respectively, with white and blue light scanners (p<0.045).

Conclusion: Our results indicate a good reproducibility of prepared tooth impression digitized with blue light scanner more than that with white light scanner.
KEYWORD
white light scanner, blue light scanner, reproducibility, color-difference-map
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)