KMID : 0362120160380020063
|
|
Journal of Technologic Dentistry 2016 Volume.38 No. 2 p.63 ~ p.68
|
|
Evaluation of internal adaptation of PMMA 3-unit bridge manufactured by 5-axis milling machine
|
|
Kim Chong-Myeong
Kim Jae-Hong Kim Ji-Hwan Kim Woong-Chul
|
|
Abstract
|
|
|
Purpose: The purpose of this study was to assess the internal fitness of the PMMA 3-unit bridge that was fabricated with 5-axis milling machine and to verify the clinically allowable values.
Methods: For fabrication of the crown bridge in this study, 25-27 abutment teeth were used. The prepare abutment teeth were scanned with a scanner and 3-unit bridge was designed by using design software. Upon the completion of the design, the 3-unit bridge was fabricated by using a PMMA block with 5-axis milling machine. The internal surface of the fabricated 3-unit bridge was scanned by using a scanner and the difference between the 3-unit bridge and the abutment teeth was assessed by merging them together.
Results: RMS¡¾SD values for PRE group, MOL group, and BRI group were 51.2¡¾18.2, 44.8¡¾10.0, and 52.1¡¾8.3§, respectively. The mean of the PRE group was bigger than that of the MOL and BRI group; however, statistically significant difference was not found (p>0.05).
Conclusion: The PMMA 3-unit bridge that was fabricated with 5-axis milling machine presented stable internal values for each crown and overall internal values were within the range of clinically allowable values.
|
|
KEYWORD
|
|
Dental CAD/CAM, Internal adaptation, Provisional crown, Subtractive method, Threedimensional, 5-axis milling
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|