KMID : 0362120160380030127
|
|
Journal of Technologic Dentistry 2016 Volume.38 No. 3 p.127 ~ p.133
|
|
Observation of Shape after sinter of Dental Co-Cr sinter metal
|
|
Song Joon-Boo
Kim Kap-Jin
|
|
Abstract
|
|
|
Purpose: Currently advanced in Dental CAD/CAM technology increase a use of Co-Cr sinter metal block at Dental CAD/CAM part traditionally it has been being used with metal casting method. There is an advantage that can leave out a step of investment and casting as well as reducing a working time to compare with conventional casting method in a dry milling.
Methods: In this research, compare a deformation of before and after sinter result of Co-Cr sinter metal block. Design a specimen figure by 3D CAD software and transformed it to a STL file can be used at Dental CAD/CAM. With a transformed STL file, milled a Co-Cr sinter metal specimen by using a Dental CAD/CAM dry milling machine. It arrived at the following conclusions after measuring an outer form and thickness of a machined specimen and then after sinter measure it again in a way of before sinter measurement method.
Results: It is confirmed that there is no error while a 3D design figure specimen is transformed to a Dental CAD data. It is observed that there is no error at Co-Cr sinter metal specimen which consider a length of single coping and bridge.
Conclusion: It is observed that there is no deformation at a specimen of AS05 and AB05 are made of 0,5mm thickness. On the other hand, the out of range of deformation is observed at a specimen of AS10 and AB10 which are made of 1mm thickness.
|
|
KEYWORD
|
|
Dental CAD/CAM, Co-Cr sinter metal, Dry milling, Sinter deformation
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|