The degree of conversion of dual-cured resin cement as a function of transmittance and thickness
Noh Hyeong-Rok

Joo Kyu-Ji
Sun Gum-Ju
Abstract
Purpose: The purpose of this study was to know of photopolymerization effect of self-etch dual-cured resin cement on different transmittance and thickness of zirconia disks.

Methods: The two types of transparent and opaque zirconia speciments were prepared. The five speciments of each groups were seperated with 0.5§® and 1.0mm thickness. Degree of conversion(DC) were studied by FT-IR spectroscopy using ATR method before and after irradidaion for 40 sec.

Results: The relative DC was showed the higher results of ZS5 as compared with ZS10 (p < 0.05). And OP5 and OP10 were lower results than ZS10 (p < 0.05).

Conclusion: The photopolymerization effect of dual-cured resin cement were affected by the transmittance and thickness of zirconia.
KEYWORD
degree of conversion, zirconia, self-etch dual-cured cement, FT-IR