Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0362120170390010017
Journal of Technologic Dentistry
2017 Volume.39 No. 1 p.17 ~ p.24
Assessment of internal fitness on resin copings fabricated by 3 - ways methods: Three - dimensional analysis
Kang Seen-Young

Park Jin-Young
Kim Dong-Yeon
Kim Woong-Chul
Abstract
Purpose: The purpose of this study was to evaluate the internal fitness of the resin coping that was fabricated by the
traditional and Digital manufacturing methods through 3-dimensional analysis.

Methods: maxillary right second molar was chosen implant master model. Custom-built impression trays were
manufactured. After screwing the pick-up impression coping onto the master cast, impressions were made with silicone
impression. The Working model was then made with type IV stone. The coping was fabricated: SLAC group (n=8), APPC
group (n=8), LAPC group (n=8) Resin coping data was measured by using a three-dimensional evaluation program. Internal fitness was calculated by RMS (Root Mean Square).It measures mean and Standard Deviation (SD).

Results: Three groups are measured 47.11¡¾(3.08)§­ total RMS of SLAC group, 48.35(¡¾1.55§­) for total RMS of LAPC
group, 43.45¡¾2.09§­ for total RMS of APPC group. Measured value is gradually increased. Followed by autopolymerized
pattern resin; Stereolithography resin, Light-activated pattern resin But there were no differences stastically(P>0.321).

Conclusion: Evaluation of internal fitness on Resin copings was fabricated by three?ways methods showed that no
differences statistically significant and clinically acceptable results.
KEYWORD
Light-activated pattern resin , Autopolymerized pattern resin , Stereolithography , 3D-mensional analysis , Coping
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)