Purpose: The purpose of this study was to evaluate the clinical acceptability of the marginal and internal gap of Co-Cr metal copings fabricated with stereolithography (SLA).
Methods: Titanium master dies were milled after scanning of the prepared tooth (n=30). For group I, Co-Cr metal copings were made from conventional lost-wax technique(LWT, n=10). For group II, the master dies were scanned and designed with CAD system. Then, metal copings were milled with Co-Cr(SUB, n=10). For group III(ADD, n=10), the scanning and design procedures were same as group II and burn-out resins were fabricated with SLA device. The marginal and internal discrepancies were measured under an optical microscope(100x) on ten reference points and were statistically analyzed with one-way ANOVA(¥á=.05).
Results: The mean total discrepancies were 53.76¡¾12.42¥ìm in the LWT group and 69.82¡¾15.48¥ìm in the ADD group. The SUB group showed the largest total mean value 110.33¡¾13.77¥ìm. There was statistically significant difference between the SUB and the other groups(P<0.05).
Conclusion : Co-Cr metal copings fabricated with SLA technology showed clinically acceptable value on marginal and internal gap and there was no statistically significant difference between conventional lost-wax technique and SLA.
|
|