KMID : 0362120190410010009
Journal of Technologic Dentistry
2019 Volume.41 No. 1 p.9 ~ p.19
Comparison the fit of three-unit metal framework fabricated by wax milling method and digital light projection method
Lee Jung-Hwan

Ahn Jae-Seok
Abstract
Purpose: This study was conducted to comparative evaluate the marginal and internal gap of three-unit metal frameworks(Co-Cr) fabricated by wax milling method and digital light projection method of CAD/CAM systems.

Methods: All the specimens were fabricated by three different fabrication methods: conventional wax up with casting(CWC), milled wax block with casting(MWC), digital light projection with casting(DLPC) (n=10 each). The marginal and internal fits of specimens were examined using a replica technique. The light-body silicone thickness was measured at 8 reference points(each abutment: 16 measurements). All measurements were conducted by a stereomicroscope. Digital photo were taken at 150¡¿ magnification and then analyzed using a measurement software. The Mann-Whitney test was used for analyzing the results.

Results: Statistically significant differences were found between the fabrication methods(p<0.001). The mean(SD) is ¥ìm for fabrication methods, the mean marginal fit were recorded respectively, CWC 63(38), MWC group 50(33), DLPC 103(54) and the mean internal fit CWC 96(47), MWC group 116(41), DLPC 138(66).

Conclusion : The marginal and internal fit were statistically different according to the fabrication methods(p<0.001). In all fabrication methods, the greatest misfit was found the occlusal area of all specimens.
KEYWORD
Accuracy, Marginal and internal fit, Marginal discrepancies, Metal framework, Three unit substructure