KMID : 0362319940190020499
|
|
Journal of Korean Academy of Operative Dentistry 1994 Volume.19 No. 2 p.499 ~ p.512
|
|
An electrochemical study on microleakage of retrograde filling using different retrograde filling materials, root resection angle and cavity preparation instruments
|
|
|
|
Abstract
|
|
|
The purpose of this study was to evaluate the microleakage electrochemically using different retrograde filling materials, different root resection angle, and different cavity preparation instruments.
@ES Experimental groups :
@EN Group 1. No bevel, cavity preparation with ultrasonic instruments, amalgam filling
@ES The results were as follows :
@EN 1. The group with Super EBA cement filling showed the least marginal leakage from second to fourth day(p<0.05), there was no significant difference between the group with amalgam filling during eighth to eighteenth day(p>0.05), but after the
nineteenth day here was a higher marginal leakage than the group with amalgam filling(p<0.05).
|
|
KEYWORD
|
|
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|