Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0362320100350060429
Journal of Korean Academy of Operative Dentistry
2010 Volume.35 No. 6 p.429 ~ p.435
Study of endodontic working length of Korean posterior teeth
Kim Jeong-Yeob

Lee Sang-Hoon
Lee Kwang-Hee
Park Sang-Hyuk
Abstract
Objectives: The aim of this study was to investigate average working lengths of Korean posterior teeth and evaluate validity of endodontic file length.

Materials and Methods : The endodontic working length of the posterior teeth of 670 Korean patients were measured than each mean value and standard deviation were investigated than the frequency deviation and standard deviation per each length were calculated.

Result: Among the canals of premolar, 66.5% of canal length was marked under 20 mm by endodontic working length and 95.4% could be measured under 22 mm and Among the canals of molars, 95.5% of canal length was marked under 20 mm endodontic working length.

Conclusions: With the result of measurement of endodontic working length of premolars of Korean, it suggested that 23 mm endodontic file is more proper than the 21 mm and 25 mm file on the market.
KEYWORD
Molar, Ni-Ti file, Premolar, Working length
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)