Journal of Korean Academy of Prosthodontics
2004 Volume.42 No. 6 p.679 ~ p.684
MARGINAL FIT OF THE AURO GALVANO CROWN SYSTEM MADE USING THE ELECTROFORMING TECHNIQUE
Yang Jae-Ho

Lee Jai-Bong
Lee Sun-Hyung
Song Tae-Jin
Han Jung-Suk
Abstract
Statement of problem. There have been few studies about the marginal fit of Auro Galvano Crowns.

Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations.

Material and methods. The in vitro marginal discrepancies of metal-ceramic, Auro Galvano Crown and coping were evaluated and compared. The Auro Gavano Crowns were made from one extracted maxillary central incisor prepared by milling machine. 30crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results.

Results. Mean marginal gap dimensions and standard deviations at the marginal opening for the anterior single crowns were 74¡¾21mum for the control (metal-ceramic restoration), 45¡¾11mum for Auro Galvano Crown coping, and 51¡¾9mum for the Auro Galvano Crown.

Conclusions. Auro Calvano Crown showed significantly smaller (P<.05) marginal gap than the control. Ceramic application did not significantly affected the marginal fit of Auro Galvano Crown. (P>.05)
KEYWORD
Marginal fit, Electroforming technique, Auro Galvano Crown