Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0362420050430050662
Journal of Korean Academy of Prosthodontics
2005 Volume.43 No. 5 p.662 ~ p.670
The effect of preparation procedure on implant-abutment joint stability
Lee Jang-Wook

Kim Chang-Whe
Jang Kyung-Soo
Lim Young-Jun
Abstract
Statement of problem: Little is known about the effect of abutment preparation procedure on de-torque values in different implant platform and the relationship of final de-torque values with different implant platform size.

Purpose: This study evaluated the effect of abutment preparation procedure on de-torque values in different implant platform and the relationship of final de-torque values with different implant platform size.

Materials & Methods: Six ITI implants (2 narrow-neck implants, 2 regular-neck implants, 2 wide-neck implants) and six Bra.nemark implants (2 narrow platforms, 2 regular platforms, 2 wide platforms) were embedded in each acrylic resin block with epoxy resin. Eighteen synOcta(R) abutments (6 narrow-neck implant-abutments, 6 regular-neck implant-abutments, 6 wide-neck implant-abutments) and eighteen esthetic abutments (6 narrow platform-abutments, 6 regular platform-abutments, 6 wide platform-abutments) were tightened to each implant with digital torque gauge. Initial de-torque values were measured using digital torque gauge. After preparation of abutments, Final de-torque values were measured with digital torque gauge.

Results & Conclusion: 1. Screws loosening or abutments motion were not detected in all experimental group, but some scratches of implant-abutment joints were detected in all group. 2. Reduction ratios of final de-torque values were greater than initial de-torque values in all measured group, except in narrow-neck implant-abutment group (p<0.05). 3. Reduction ratios of final de-torque values in wide-neck implant-abutment group were greater than regular-neck implant-abutment group (p<0.01). 4. The greatest standard deviation value was detected in wide platform group in both implant systems.
KEYWORD
Preparable abutment, Initial de-torque value, Final de-torque value, Screw loosening, joint stability
FullTexts / Linksout information
   
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed