Abstract
Purpose: The purpose of this study was to evaluate the fit of zirconia core using MAD/MAM system comparing to that of conventional metal-ceramic and CAD/CAM system.

Materials and Methods : Duplicating the prepared resin tooth, 50 improved stone dies were fabricated. These dies are classified as a group of 5 to create the core. The groups were composed of metal-ceramic, Cercon¢ç, Ceramill¢ç, Rainbow¢â, and Zirkonzhan¢ç. Each core was cemented to stone die, and then, absolute marginal discrepancy was measured with microscope at a magnification of ¡¿50. Statistical analysis was done with one-way ANOVA test and Tukey¡¯s HSD test.

Results: The mean absolute marginal discrepancy for metal-ceramic was 51.97 ¡¾ 23.38 ¥ìm, for Cercon¢ç was 62.16 ¡¾ 25.88 ¥ìm, for Ceramill¢ç was 67.64 ¡¾ 40.38 ¥ìm, for Rainbow¢â was 125.07 ¡¾ 42.19 ¥ìm, and for Zirkonzhan¢ç was 105 ¡¾ 44.61 ¥ìm.

Conclusions: 1. Fit of margin was identified as in the order of metal-ceramic, Cercon¢ç, Ceramill¢ç, Zirkonzhan¢ç, and Rainbow¢â. 2. Absolute marginal discrepancy of the zirconia core that designed by MAD/MAM system had significant differences in order of Ceramill¢ç, Zirkonzhan¢ç, and Rainbow¢â. 3. The mean absolute marginal discrepancy between Cercon¢ç and Ceramill¢ç did not show significant differences.
KEYWORD
Zirconia, core, MAD/MAM, Marginal discrepancy