PURPOSE: The purpose of this study was to assess the marginal fit of three-unit bridges produced using LAVA CAD/CAM (computer-aided design/computer-aided manufacturing) system and conventional PFG in vitro.
MATERIALS AND METHODS: #11, 13 resin teeth were prepared on dentiform, then duplicated. Twenty resin models were fabricated, ten for PFG 3-unit bridges and ten for LAVA 3-unit bridges. Each bridge was cemented on the resin model. Marginal discrepancy was measured with stereoscopic microscope (Nikon DS-Fi 1, Nikon, Japan) at a magnification of ¡¿75. Independent t-test was done for the statistical analysis.
RESULTS: The mean marginal discrepancy values and standard deviations of the PFG bridges was 97.1 ¡¾ 18.7 § for incisors, 76.6 ¡¾ 21.8 § for canines; that of the LAVA bridges was 90.4 ¡¾ 26.7 § for incisor, 110.2 ¡¾ 30.2 § for canines. The mean marginal discrepancy between PFG and LAVA for incisor did not show significant difference (P>.05). But for canine, the mean marginal discrepancy of PFG bridges was smaller than that of LAVA bridges (P<.05).
CONCLUSION: The LAVA CAD/CAM 3-unit bridges and the PFG 3-unit bridges showed clinically acceptable marginal discrepancy.
|
|