KMID : 0362420110490040354
|
|
Journal of Korean Academy of Prosthodontics 2011 Volume.49 No. 4 p.354 ~ p.361
|
|
Surveyed restoration and RPD framework design utilizing electronic surveying
|
|
Hong Yong-Shin
Park Eun-Jin Kim Seong-Kyun Koak Jai-Young Heo Seong-Joo Park Ji-Man
|
|
Abstract
|
|
|
There are still many limitations on fabricating dentures using digital method while computerized production of fixed prostheses utilizing intraoral scanner and CAD/CAM technology has propagated rapidly. Recently the digital solution of fabricating removable partial denture by applying haptic input device, electronic surveying, and rapid prototyping was introduced. In this case presentation, five patients were treated with surveyed crown and removable partial dentures by this digital solution. Fit of dentures was excellent except for one case which showed morphological difference between the actual teeth and that of master cast by the erroneous impression process. There also was not any problem of stability and retention after adaptation in the clinical setting.
|
|
KEYWORD
|
|
Haptic input device, Electronic surveying, CAD, Rapid prototyping
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|