Surveyed restoration and RPD framework design utilizing electronic surveying
Hong Yong-Shin

Park Eun-Jin
Kim Seong-Kyun
Koak Jai-Young
Heo Seong-Joo
Park Ji-Man
Abstract
There are still many limitations on fabricating dentures using digital method while computerized production of fixed prostheses utilizing intraoral scanner and CAD/CAM technology has propagated rapidly. Recently the digital solution of fabricating removable partial denture by applying haptic input device, electronic surveying, and rapid prototyping was introduced. In this case presentation, five patients were treated with surveyed crown and removable partial dentures by this digital solution. Fit of dentures was excellent except for one case which showed morphological difference between the actual teeth and that of master cast by the erroneous impression process. There also was not any problem of stability and retention after adaptation in the clinical setting.
KEYWORD
Haptic input device, Electronic surveying, CAD, Rapid prototyping
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed