Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0362720040420090632
Journal of the Korean Dental Association
2004 Volume.42 No. 9 p.632 ~ p.637
Yang Sung-Hyun

Lee Ju-Hee
Abstract
Purpose : The purpose of this study was to compare the proximal marginal gap widths between two different indirect composite resin systems.

Materials and Methods : Two types of materials were used in this study : Artglass (Heraeus Kulzer Co, Wehrheim, Germany) and TESCERA (BISCO. Ins, U. S. A.). The metal model prepared in the MOD cavity was impressed with 40 impression bodies with the same kind of silicon (PRESIDENT microsystem, regular / light body, Coltene, Swiss).
Artglass : 10 inlay bodies (2 layers), 10 inlay bodies (3 layers)
TESCERA : 10 inlay bodies (2 layers), 10 inlay bodies (3 layers)
Marginal accuracy was measured by the Image Analyzer and microscope on six points of a metal model.

Results : The gap widths in the two types of TESCERA inlay were similar to those of the two types of Artglass inlay (p>0.05). However, in this study the maximum gap width was 137 §­ for the Artglass 2 layers and there were three failed inlay bodies (gap width>100 §­). 96.7% of the Artglass and 98.3% of the TESCERA gap widths were under 100 §­. There was a total of 5 inlay bodies with failed gap widths over 100 §­.

Conclusion : Within the limitations of this study, the MOD inlays of the indirect composite resins were acceptable for clinical application on the proximal margin with gap width under 100 §­.
KEYWORD
gap width, indirect composite resin, MOD inlay, proximal margin
FullTexts / Linksout information
 
Listed journal information