KMID : 0362720150530050368
|
|
Journal of the Korean Dental Association 2015 Volume.53 No. 5 p.368 ~ p.376
|
|
A study on simplified procedure of enhanced designed implant drill
|
|
Yoon Ji-Hoon
Jeon Gye-Rok Yun Mi-Jung Huh Jung-Bo Jeong Chang-Mo
|
|
Abstract
|
|
|
Purpose : The objective of this research was to develop a more simplified drilling procedure with an enhanced implant drill.
Materials and Methods : The drill enhanced design factors enabled implantation of Dia. 5.0mm fixture with only 2 times drilling which is more simplified drilling procedure. The enhanced drill was designed with 2 flutes, 2-phase or 3-phase formed drill tip and 25 degrees of helix angle. The proposed drilling procedure (2 times) was compared with a general drilling process (4 times) in terms of temperature changes, cutting time and ISQ value.
Results : The simplified drilling procedure indicated less heat than a conventional drilling procedure (p<0.05). The enhanced drill showed significantly shorter drilling time than a conventional drill (p<0.05). On the other hand, higher insertion torque and ISQ value were observed on the the suggested drilling procedure than the conventional drilling procedure (p<0.05).
Conclusion : A simplified drilling procedure with the newly designed drill could provide higher effectiveness and safety of dental implant operations under properly controlled external conditions, such as irrigation and RPM of drilling.
|
|
KEYWORD
|
|
drill design, simplified drilling procedure, heat generation, cutting efficiency, initial stability
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|