KMID : 0362720180560120686
|
|
Journal of the Korean Dental Association 2018 Volume.56 No. 12 p.686 ~ p.694
|
|
Evaluation of sealant microleakage using Swept-Source Optical Coherence Tomography
|
|
Nam Sang-Mi
Ku Hye-Min Lee Eun-Song Kim Baek-Il
|
|
Abstract
|
|
|
Purpose: The aim of this study was to evaluate the validity of swept-source optical coherence tomography (SS-OCT) for detecting sealant microleakage.
Materials and Methods: A total of 31 extracted sound human molar, assigned as suitable for sealant application, were chosen and divided into two groups: (1) no microleakage group and (2) microleakage group by applying sealant using the different methods. All specimens were immersed in 1% methylene blue for 24 h and sectioned to confirm the absence or presence of sealant microleakage as a gold standard method. Subsequently, all the sectioned specimens were digitally photographed using a microscope with a magnification of 50. Presence of microleakage was evaluated on a 2-point rating scale. The association of histological method with conventional methods (visual and tactile assessment) and SS-OCT was assessed using a chi-squared test. The intra- and inter-examiner reliability was calculated using Cohen¡¯s Kappa.
Results: The SS-OCT showed a sensitivity of 0.73 and a specificity of 1.00, while visual and tactile assessment showed a sensitivity of 0.67 and a specificity of 0.86. The inter-examiner reliability of SS-OCT was 0.79, whereas that of the visual and tactile assessment was 0.53.
Conclusions: SS-OCT can be used to non-invasively detect sealant microleakage and to monitor pit and fissure sealant in the clinics.
|
|
KEYWORD
|
|
Swept-source optical coherence tomography (SS-OCT), Pit and fissure sealant, Microleakage
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|