KMID : 0362720200580040194
|
|
Journal of the Korean Dental Association 2020 Volume.58 No. 4 p.194 ~ p.205
|
|
Accuracy of inter-arch measurements performed on digital models generated using two types of intraoral scanners: Ex vivo study
|
|
Yoo Jo-Kwang
Kang Yoon-Koo Lee Su-Jung Kim Seong-Hun Moon Cheol-Hyun
|
|
Abstract
|
|
|
Objective: The purpose of this study was to evaluate the accuracy of the inter-arch relationship of digital models generated
using two types of intraoral scanners.
Methods: In total, 34 plaster model samples were used. Two corresponding digital models were created using two types
of intraoral scanners. A total of 15 variables were measured. The plaster model was directly measured using a digital caliper, while the digital models were measured using a software. The accuracy of the measurements was evaluated using repeated measures analysis of variance and the Friedman test.
Results: Among the 15 measurements, 6 measurements[Overjet, Overbite, DZ_11-41 (Distance between the gingival zenith
of maxillary right central incisor and mandibular right central incisor), DZ_16-46 (Distance between the gingival zenith
of maxillary right first molar and mandibular right first molar), DZ_13-33 (Distance between the gingival zenith of maxillary
right canine and mandibular left canine), and DZ_23-43 (Distance between the gingival zenith of maxillary left canine and
mandibular right canine)]showed statistically significant differences, with DZ_23-43 showing the largest difference of 0.18
mm. The other measurements showed no statistically significant differences.
Conclusions: Regardless of the type of scanner used for preparation, digital models can be used as clinically acceptable
alternatives to conventional plaster models.
|
|
KEYWORD
|
|
Digital models, 3D intraoral scanner, Inter-arch measurements
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|