Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0362720220600040231
Journal of the Korean Dental Association
2022 Volume.60 No. 4 p.231 ~ p.240
Strategy for Reducing Postoperative Hypersensitivity in Class II Direct Restoration using Composite Resin
Kim Do-Hyun

Abstract
One of the major causes of postoperative hypersensitivity following direct composite resin restoration is microleakage. Adequate adhesive technique, incremental filling, lining of elastic material, and regulation of light curing speed would be helpful for reducing microleakage via polymerization shrinkage. In proximal box restoration, pre-wedging, sectional matrix system, and proper resin applicator are recommended to form adequate proximal contact and contour.
KEYWORD
class II cavity, direct restoration, postoperative hypersensitivity, composite resin
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)