KMID : 0363120090220020124
Korean Journal of Pain
2009 Volume.22 No. 2 p.124 ~ p.129
The Aspiration of Injected Air via an Epidural Catheter as an Indicator for Appropriate Placement of the Catheter in the Epidural Space
Cheong Soon-Ho

Park Dae-Sik
Moon Sung-Ho
Cho Kwang-Rae
Lee Sang-Eun
Kim Young-Hwan
Lim Se-Hun
Lee Jeong-Han
Lee Kun-Moo
Choe Young-Kyun
Kim Young-Jae
Shin Chee-Mahn
Abstract
Background: The "gold standard" for proper epidural catheter positioning is a clinical response, as assessed by a pinprick test. Yet it may take time or it may be difficult to perform this test after epidural catheter placement in sedated or uncooperative patients or during general anesthesia. We assessed the usefulness of aspirating injected air via an epidural catheter as an indicator of correct epidural catheter placement.

Methods: We surveyed 200 patients who underwent surgery under general or epidural anesthesia. A Tuohy needle was inserted into the epidural space with using the hanging drop technique. After placement of the epidural catheter, 3 ml of air was injected via the catheter, and then the volume of aspirated air was measured.

Results: The mean volume of aspirated air was 2.3 ¡¾ 0.7 ml (75% of the injected air volume) and this ranged from 0 to 3 ml.

Conclusions: Aspiration of injected air is a simple alternative method for identifying the appropriate placement of epidural catheters in the epidural space.
KEYWORD
air aspiration, epidural anesthesia, epidural catheter