Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0363120100230010011
Korean Journal of Pain
2010 Volume.23 No. 1 p.11 ~ p.17
Determination of Adequate Entry Angle of Lumbar Sympathetic Ganglion Block in Korean
Kim Won-Ho

Lee Chul-Joong
Kim Tae-Hyung
Sim Woo-Seok
Kim Sang-Kwon
Abstract
Background:The target of lumbar sympathetic ganglion block is the anterolateral surface of the L2, 3 and 4 vertebral bodies, where the lumbar sympathetic ganglion usually lies. In most cases, a block-needle is inserted approximately 5-8 cm lateral to spinous process on the skin and directed to the anterolateral surface of vertebral body obliquely. The purpose of this study is to determine the safe entry angle and entry point in Korean by using the abdominal CT scan images.

Methods:The abdominal CT images of eighty five patients were recruited to this study. The minimal angle aimed at the lumbar sympathetic ganglion that can pass through the lateral aspect of body and maximal angle that avoids puncturing the kidney, ureter or retroperitoneal space were measured. The distance from midline to skin entry point was also measured.

Results:There was no significant difference in entry angle among L2, 3, and 4 level. The entry angle was similar in the right and left side, and in males and females. The entry angle of old age group was significantly smaller than that of young age group. The calculated safe entry angle was 30.5 ¡¾ 0.4¡Æ and entry point was 7.7 ¡¾ 0.2 cm and 6.7 ¡¾ 0.1 cm lateral from midline in males and females respectively.

Conclusions:These measurements can be used as a reference for lumbar sympathetic ganglion block and radiofrequency lesioning. Prior to performing the lumbar sympathetic ganglion block for cancer patients, the abdominal CT scan should be reviewed to prevent complications.
KEYWORD
entry angle, entry point, lumbar sympathetic ganglion block, safety
FullTexts / Linksout information
 
Listed journal information
SCI(E) ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø