Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0363320150360030228
Journal of Korean Oriental Internal Medicine
2015 Volume.36 No. 3 p.228 ~ p.235
Diagnostic Tool for Cold Sensation of Hands: A Preliminary Study
Ko Seung-Woo

Park Jong-Joo
Kong Kyung-Hwan
Go Ho-Yeon
Abstract
Objectives: The aim of this study was to find an effective medical device to detect cold sensation of hands.

Methods: Patients with cold sensation of hands (N=42) were recruited in July 2013. We surveyed patients¡¯ general characteristics, severity of cold sensation, body temperature in Nogung (PC8) and Hyeopbaek (LU4) measured with a digital thermometer, digital infrared thermal imaging, and pulse wave velocity.

Results: The relation between severity of cold sensation and temperature in Nogung (PC8) and Hyeopbaek (LU4) was statistically significant. The results showed a higher correlation of severity of cold sensation with Nogung (PC9) than with Hyeopback (LU4) temperature. No other indices were statistical significant.

Conclusions: Measuring the Nogung (PC9) temperature is most reasonable for assessing the severity of cold sensation of hands. To generalize this result, however, a large-scale study is warranted.
KEYWORD
cold sensation, thermometer, DITI, PWV, standardization diagnosis
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)