Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0363819910250010037
Korean Journal of Nuclear Medicine
1991 Volume.25 No. 1 p.37 ~ p.45
Quantitative assessment of myocardial infarction by in-III antimyosin antibody
°íâ¼ø/Koh CS
À̸íö/Á¤Áرâ/¹Ú¿µ¹è/¹®´ëÇõ/ÀÌ°æÇÑ/ÃÖÀ±È£/Lee MC/Chung JK/Park YB/Moon DH/Lee KH/Choi YH
Abstract
Infarct size is a major determinant of prognosis after acute myocardial infarction. Up to date, however, clinically available tests to estimate this size have not been sufficient]y accurate. Twelve lead electrocardiogram and wall motion abnormality measurement are not quantitative, and creatine phophokinase (CPK) measurement is inaccurate in the presence of reperfusion or right ventricular infarction. Methods have been developed to localize and size acute myocardial infarcts with agents that are selectively sequestered in areas of myocardial damage, but previously used agents have lacked sufficient specificit:y. Antibodies that bind specifically only to damaged myocardial cells may resolve this problem and provide an accurate method for noninvasively measuring infarct size. We determined t.he accuracy with which infarcted myocardial mass can be measured using single photon emission computed tomography (SPECT) and radiolabeled antimyosin antibodies. Seven patients with acute myocardial infarction and one stable angina patient were injected with 2 mCi of Indium-111 labeled antimyosin antibodies. Planar image and SPECT was performed 24 hours later. None of the patients had history of prior infarcts, and none had undergone reperfusion techniques prior to t.he study, which was done within 4 days of the attack. Planar image showed all infarct patients to have postive uptakes in the cardiac region. The location of this uptake correlated to the infarct site as indicated by electrocardiography in most of the cases. The angina patient, however, showed no such abnormai uptake. Infarct size was determined from transverse slices of the SPECT image using a 45% threshold value obtained from a phantom study.Measured infarct size ranged from 40 to 192 gr. There was significant correlation between the infarct size measured by SPECT and that estimated from serial measurements of CPK (r=0.73, p<0,05). These date suggest that acute myocardiaI infarct size can be accurately measured from SPECT Indium-111 antimyosin imaging. This method may be especially valuable in situations where other methods are unreliable, such as early reperfusion technique, right ventricular infarct or presence of prior infarcts.
KEYWORD
FullTexts / Linksout information
 
Listed journal information
KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø