Effects of Autotransfusion using Cell Saver in Cardiac Surgery
¾È¿í¼ö
ÃÖº´Ã¶/À̼·/Çã¿ë/±èº´¿­/ÀÌÁ¤È£
Abstract
Autologous blood transfusion is a common method of reducing the need for homologous blood transfusion during cardiac operations.
Between June 1991 and May 1992, 12 cases(Group I) were experienced autologous blood transfusion using Cell Saver undergoing double valve replacement or redo-valve repalcement. Control group (N=12, Group II) was selected to above similar operation
during
same period.
The Cell Saver system(Haemonetics Corp.) was employed for autologous blood transfusion. The blood shed in the operative field before and after cardiopulmonary bypass and remained cardiotomy reservior was aspirated by means of a locally
heparinized
colleoting system. After centrifused salvaged blood, the resulting red cell concentrate reinfused suvsequently.
The patients receiving autologous blood transfusion required significantly less homologous blood transfusion than their control group. (Grou I ; 3519¡¾869, group II ; 4622¡¾ 856, Respectively ; P=0.095) there were no clinical infections in the
autotransfusion group. And there was no apparent intergroup difference of the clinical findings, hematologio datas and coagulation parameters.
We conclude the autotransfusion using Cell Saver is effective for reducing of the homologlous blood transfusion in cardiac surgery.