KMID : 0364019950280110983
|
|
Korean Journal of Thoracic and Cardiovascular Surgery 1995 Volume.28 No. 11 p.983 ~ p.988
|
|
Clinical Improvement after Modified Blalock-Tassig Shunt in Cyanotic Heart Disease
|
|
|
|
Abstract
|
|
|
From January 1983 to December 1994, 48 cyanotic patients were underwent a subclavian arterypulmonary artery shunt using polytetrafluoroethylene (PTFE) for the purpose of improvement of reduced pulmonary blood flow. The diameters of the PTFE used
were
4mm (4 cases), 5mm (36 cases), and 6mm (8 cases) sizes. The effectiveness of modified Blalock-Taussig shunts was evaluated clinically and angiographically. There were 5 early deaths and 2 late deaths. There were 3 early shunt failures and 5 late
shunt
failures. The overall graft patency rate was 83.3%. Postoperative hemoglobin was reduced significantly (p=0.0011) in comparison of the preoperative and postoperative hemoglobin, SaO2, PaO2, and cardiothoracic ratio.
(Korean J Thorac Cardiovasc Surg 1995;28:983-8)
|
|