KMID : 0364020070400110798
|
|
Korean Journal of Thoracic and Cardiovascular Surgery 2007 Volume.40 No. 11 p.798 ~ p.801
|
|
Thoracoscopic Removal of an Intrapulmonary Sewing Needle -A case report-
|
|
Yu Jeong-Hwan
Kang Shin-Kwang Na Myung-Hoon Lim Seung-Pyung Lee Young Yu Jae-Hyeon
|
|
Abstract
|
|
|
A 24 year old man visited our hospital, because an intrapulmonary foreign body had been found incidentally. Simple chest X-ray showed a 5 cm sized foreign body of metallic density, and chest CT confirmed the foreign body, which was like a sewing needle, in the left upper lobe. We performed a simple extraction of the foreign body using VATS (Video Assisted Thoracic Surgery). After the operation, the patient was discharged without any complications. (Korean J Thorac Cardiovasc Surg 2007;40:798-801)
|
|
KEYWORD
|
|
Foreign body, Thoracoscopy
|
|