Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0364020090420040528
Korean Journal of Thoracic and Cardiovascular Surgery
2009 Volume.42 No. 4 p.528 ~ p.531
Pyriform Sinus Perforation with Deep Neck Infection Caused by Transesophageal Echocardiography during Coronary Artery Bypass Grafting -A case report-
Chang Hyung-Woo

Kim Ki-Bong
Yoo Jae-Suk
Hwang Ho-Young
Abstract
Transesophageal echocardiography (TEE) is widely used to evaluate the heart function and the result of surgery during a cardiac operation. The incidence of complications associated with TEE is low, yet critical complications such as lower pharyngeal injury and esophageal perforation may happen. We report here on a case of 77-year old male patient who suffered from injury to the pyriform sinus and concurrent deep neck infection after off pump coronary artery bypass surgery and intraoperative TEE. (Korean J Thorac Cardiovasc Surg 2009;42:528-531)
KEYWORD
Transesophageal echocardiography, Coronary artery bypass surgery, Complication
FullTexts / Linksout information
  
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø