Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0364020100430010086
Korean Journal of Thoracic and Cardiovascular Surgery
2010 Volume.43 No. 1 p.86 ~ p.88
Extraction of an Infected Permanent Pacemaker Lead Using Cardiopulmonary Bypass -2 case reports-
Oh Tak-Hyuck

Kim Gun-Jik
Lee Jong-Tae
Abstract
Implanting a pacemaker is the most often used intervention for treating bradycardia. The most commonly used pacemaker is the intracardiac pacemaker, yet it can have many complications. An infected pacemaker can spread to systemic infection and the condition of the patient can quickly get worse, so if an infected pacemaker is suspected, then the pacemaker must be removed. Apart from the use of interventional methods such as a loop or a weight, we can take a more aggressive approach by using extracorporeal circulation for removal of the pacemaker. We report here on two cases in which extracorporeal circulation was used to remove the infected pacemakers.
KEYWORD
Pacemaker, Cardiopulmonary bypass, Infection
FullTexts / Linksout information
  
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø