Duodenal Perforation Caused by an Inferior Vena Cava Filter
Bae Mi-Ju

Chung Sung-Woon
Lee Chung-Won
Kim Sang-Pil
Song Seung-Hwan
Abstract
The inferior vena cava (IVC) filter is known as an effective and safe method for preventing fatal pulmonary thromboembolism in patients with deep vein thrombosis. Usually, the remaining IVC filters are asymptomatic and do not cause clinical problems. We report a case of duodenal perforation caused by a remaining IVC filter.
KEYWORD
Venous disease, Complication, Foreign bodies, Penetrating trauma, Vena cava filters