Fixation of Traumatic Sternal Fractures Using SternaLock Plating System
Park Jong-Bin

Lee Han-Pil
Yoo Dong-Gon
Kim Jong-Wook
Cho Won-Chul
Abstract
A 43-year-old man experienced chest trauma due to a car accident. Compound sternal fractures with severe dislocation were seen on computed tomography of the chest. Using a SternaLock plating system with manual reduction, fixation of the sternal fracture was successfully performed. There were no complications related to the operation.
KEYWORD
Sternum, Fracture, Fixation