Application of Whole Body Counter to Neutron Dose Assessment in Criticality Accidents
O kurihara
N Tsujimura/K Takasaki/T Momose/Y Maruo
Abstract
Neutron dose assessment in criticality accidents using Whole Body Counter (WBC) was proved to be an effective method as rapid neutron dose estimation at the JCO criticality accident in Tokai-mura. The 1.36MeV gamma-ray of 24Na in a body can be detected easily by a germanium detector. The Minimum Detectable Activity (MDA) of 24Na is approximately 50Bq for 10miniute measurement by the germanium-type whole body counter at JNC Tokai Works. Neutron energy spectra at the typical shielding conditions in criticality accidents were calculated and the conversion factor, whole body activity-to-organ mass weighted neutron absorbed dose, corresponding to each condition were determined. The conversion factor for uncollied fission spectrum is 7.7 [(Bq24Na/g23Na)/mGy].