Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0364920080330010041
Journal of Radiation Protection and Research
2008 Volume.33 No. 1 p.41 ~ p.46
Finger Doses Received during 99mTc Injections Calculated with GEANT4
Han Dong-Hyun

Kang Sang-Koo
Kim Chong-Yeal
Abstract
To estimate the finger dose absorbed by 99mTc injection, simulations are carried out to calculate the dose equivalent of each finger per second with radioactivity of 370 MBq, based on the GEANT4 simulator. For the 99mTc source of the volume of 0.4mL and the radioactivity of 370 MBq, we obtained the dose equivalent of the right thumb (0.29¥ìSv sec-1), the right index finger (1.19¥ìSv sec-1), the right middle finger (1.07¥ìSv sec-1), the left thumb (4.36¥ìSv sec-1), and the left index finger (3.37¥ìSv sec-1), respectively. This simulation results may serve as a useful data in the prediction of finger dose absorbed by 99mTc injection.
KEYWORD
GEANT4 simulator, finger dose, dose equivalent
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)