2016 Volume.41 No. 4 p.384 ~ p.388
A Proposal on Evaluation Method of Neutron Absorption Performance to Substitute Conventional Neutron Attenuation Test
Kim Jae-Hyun

Kim Song-Hyun
Shin Chang-Ho
Choe Jung-Hun
Cho In-Hak
Park Hyun-Seo
Kim Jung-Ho
Kim Yoon-Ho
Abstract
Background: For a verification of newly-developed neutron absorbers, one of guidelines on the qualification and acceptance of neutron absorbers is the neutron attenuation test. However, this approach can cause a problem for the qualifications that it cannot distinguish how the neutron attenuates from materials.

Materials and Methods: In this study, an estimation method of neutron absorption performances for materials is proposed to detect both direct penetration and back-scattering neutrons. For the verification of the proposed method, MCNP simulations with the experimental system designed in this study were pursued using the polyethylene, iron, normal glass and the vitrified form.

Results and Discussion: The results show that it can easily test neutron absorption ability using single absorber model. Also, from simulation results of single absorber and double absorbers model, it is verified that the proposed method can evaluate not only the direct thermal neutrons passing through materials, but also the scattered neutrons reflected to the materials. Therefore, the neutron absorption performances can be accurately estimated using the proposed method comparing with the conventional neutron attenuation test.

Conclusion: It is expected that the proposed method can contribute to increase the reliability of the performance of neutron absorbers.
KEYWORD
Neutron absorber, MCNP, Criticality control, Vitrified form, Neutron absorption ability, Neutron attenuation test