Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0365420110300020012
Journal of the KLIMA
2011 Volume.30 No. 2 p.12 ~ p.15
Mortality Analysis of Implantable Cardioverter Defibrillator (ICD)
Park Kwang-Il

Abstract
Background: The beneficial effects of implantable cardioverter defibrillators (ICDs) in primary and secondary prevention patients are well established. However, data on potential differences between both groups in mortality are scarce. The aim of this study was to assess extra risk differences between primary and secondary prevention ICD recipients.

Methods: Comparative mortality figures were calculated from a source article using mortality analysis methods.

Results: Mortality ratio (MR) of primary and secondary prevention ICD recipients were 393% and 373%. Excess death rates (EDR) of both groups were 42 and 38 per 1,000.

Discussion: MR and EDR were higher in primary prevention group. But, there was no significant difference.
KEYWORD
MR, mortality ratio, EDR, excess death rate, ICD, implantable cardioverter defibrillator
FullTexts / Linksout information
Listed journal information
´ëÇÑÀÇÇÐȸ ȸ¿ø