KMID : 0366919970090010067
|
|
Sungkyun Pharmceutical Journal 1997 Volume.9 No. 1 p.67 ~ p.71
|
|
Bioequivalence of Nicotine Patches
|
|
|
|
Abstract
|
|
|
The bioequivalence of two nicotine patches was evaluated in 16 normal male volunteers (age 21¡27 yrs) following single transdermal application. Test product was "Nicostop patch" made by Sam Yang Co. and reference product was "Nicotinell TTS patch" made by Korean Searle Ciba-Geigy Co. After nicotine patches were applied onto the inside of the forearm, blood was taken at predetermined time intervals and the nicotine concentration in plasma was determined with a sensitive GC method using NPD detector. AUC and C_max the differences in AUC and C_max between two products were 5.47% and 2.70%, respectively. The powers (1-¥â) for AUC and C_max were £¾90% and 88.76%, respectively. Detectable differences(¡â) and confidence intervals were all less than 20%. All of these parameters met the criteria of KFDA for bioequivalence, indicating that "Nicostop patch" is bioequivalent to "Nicotinell TTS patch".
|
|