Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0367419940370010040
Journal of Korean Pediatric Society
1994 Volume.37 No. 1 p.40 ~ p.46
Urinary Red Cell Volume in the Diagnosis of Glomerular and Non-Glomerular Hematuria in Children
±ÇÁ¾¼³
±èµ¿¼®/±è¸í¼º/±èÁؽÄ/°­Áø¹«/Àüµ¿¼®
Abstract
Hematuria is a important clinical sign that is a consequence of significant fenal. urologic or sytemic disease. Recently the morphology of the red cell in hematuria has been used to indicate a renal or non-renal source and also the measurement of
red
cell volume by red cell analyzer has been used to distinguish glomerular from non-glomerular hematuria.
In this study. the MCV(mean corpsular red cell voume). RDW(red cell distribution width) and HDW (hemoglobin distribution width) were measured using H-1 system in57 children with hematuria to assess the diagnostic usefulness of the urinary red
cell
analyzer in the differentation of glomerular and non-glomerular hematuria. The patients were divided into two groups as glomerular diseases(40cases)and non-glomerular diseases(17 cases)and the location of the bleeding was confirmed by renal
biopsy,
radiology and the clinical findings.
@ES The results were as follows.
@EN 1) The urinary red cell MCV waslower in patients with glomerular diseases than that in patients with non-glomerular diseases (79.89 12.fl vs. 90.93 9.71fl vs. 90.93 9.71 fL; p<0.01)
2) The urinary RDW and HDW were significantly higher in glomerular diseases than those in non-glomerular diseases (RDW; 19.86 11.28% vs 11.34 5.88%, HDW; 3.37 2.07 gm vs. 1.86 1.43gm).
3) The urinary red cell MCV was correlated well with the RDW and HDW while there was no correlation between the urinary red cell MCV and the urinary SG or pH.
4) The sensitivity, specificity and positive predictability of the urinsary MCV were 37.8%, 94.1% and 93.7% and those of RDW were 62.5%, 82.3% and 89.2%
5) The sensitivity, specificity and positive predictability of the urinary HDW were 42.5%, 88.2% and 89.4%
We concluded from above date that the measurment of the urinary MCV, RDW and HDW would be useful as a primary non-invasive screening test in differentation of glomerular and non-glomerular hematuria in children.